Measured lifetimes of metastable levels of Mn X, Mn XI, Mn XII, and Mn XIII ions

Loading...
Thumbnail Image

Date

1999

Journal Title

Journal ISSN

Volume Title

Publisher

American Physical Society

Abstract

An ion storage technique, based on the capture of metastable multiply charged ions from an external ion source into a Kingdon ion trap, has been used to measure the lifetimes of eight metastable levels of Mn ions with 3s(2)3p(k) configurations, k = 1 - 4. Although several lifetime calculations exist, some of the transition wavelengths have not been previously observed in any source. The lifetimes range from 1.5-35 ms. A measurement precision as good as 0.9% was obtained in favorable cases. The measured lifetimes are tau(Mn X, 3s(2)3p(4) S-1(0)) = 2.1 +/- 0.3, tau(Mn X, 3s(2)3p(4) D-1(2)) = 18.02 +/- 0.16, tau(Mn XI, 3s(2)3p(3) P-2(3/2)) = 3.0 +/- 0.2, tau(Mn XI, 3s(2)3p(3) P-2(1/2)) = 6.17 +/- 0.29, tau(Mn XI, 3s(2)3p(3) D-2(3/2)) = 35.1 +/- 1.43, tau(Mn XII. 3S(2)3p(2) S-1(0)) = 1.5 +/- 0.2, tau(Mn XII, 3s(2)3p(2) D-1(2)) = 11.16 +/- 0.10, and tau(Mn XII, 3s(2)3p P-2(3/2)) = 31.32 +/- 1.82 ms. These results are compared with the existing theoretical calculations, which have estimated uncertainties no better than 25%. [S1050-2947(99)102903-0].

Description

Journals published by the American Physical Society can be found at http://publish.aps.org/

Keywords

TRANSITION-PROBABILITIES, FORBIDDEN LINES, CONFIGURATION, Optics, Physics, Atomic, Molecular and Chemical

Citation

D. P. Moehs and David A. Church. Phys.Rev.A 59 1884-1889 1999. "Copyright (1999) by the American Physical Society."