RCFA Case Study: Infant Mortality: Lean Solvent Centrifugal Pump Motor
Loading...
Date
2011
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Turbomachinery Laboratory, Texas A&M Engineering Experiment Station
Abstract
Introduction: •Qatargas Operating Company Limited •Refresher: Bathtub Curve & Failure Regions (i.e. Infant Mortality) Root Cause & Failure Analysis •Brief Introduction –Incident and Action Plan •Simplified System Diagram •Basic Data –Pump & Motor •Event Diagram (Timeline) •Pictures of Failed Parts •PROACT Logic Tree & Vibration Data •Root Cause(s) •Recommendations & Lesson Learned •Q&A / Thanks
Description
Case Study