NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
Modeling the effects of refrigerant charging on air conditioner performance characteristics for three expansion devices
dc.contributor.advisor | O'Neal, D. L. | |
dc.creator | Farzad, Mohsen | |
dc.date.accessioned | 2020-09-02T20:04:18Z | |
dc.date.available | 2020-09-02T20:04:18Z | |
dc.date.issued | 1990 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/DISSERTATIONS-1118187 | |
dc.description | Typescript (photocopy). | en |
dc.description.abstract | An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device on the system performance (capacity, EER, SEER, etc.) of an air conditioner. All experiments were performed according to the ASHRAE Standard [1983]. The effects of off-design refrigerant charge in the system, type of expansion device (capillary tube, TXV, and short-tube orifice), and outdoor dry-bulb temperature (82° to 100°F) on the wet and dry steady state and cyclic tests are addressed in this study. The fully charged condition was established as a base case for all the expansion device systems. A full charge was obtained by charging the unit to the superheat or subcooled condition specified by the manufacturer charging chart Once the full charge was determined, refrigerant was then added in 5% increments from -20% of full charge to +20% of full charge to cover the full range of charging conditions for a particular expansion device being tested. The investigation of off-design charging indicated that the system performance variables (total capacity, EER, and SEER) of the unit with capillary tube were more sensitive to off-design charging than the systems with TXV and short-tube orifice. From -20% to +20% charging, the capacity and EER showed a strong dependence on the outdoor temperature, but varied little with charge tor the TXV and short-tube orifice expansion systems. A -20% charging resulted in a 21% reduction in SEER while a +20% charging produced a 11% reduction in SEER for the unit with capillary tube. For the TXV, SEER dropped 2% and 8% for -20% and +20% refrigerant charging, respectively. The SEER was constant at 9.4 for ail the charging condition except for -5% charging where it peaked to 9.9 for the short-tube orifice expansion system. This trend would suggest that the range of sensitivity of an short-tube orifice system is confined within a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model... | en |
dc.format.extent | xxii, 164 leaves | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.subject | Major mechanical engineering | en |
dc.subject.classification | 1990 Dissertation F247 | |
dc.subject.lcsh | Air conditioning | en |
dc.subject.lcsh | Efficiency | en |
dc.subject.lcsh | Refrigerants | en |
dc.subject.lcsh | Heat pumps | en |
dc.title | Modeling the effects of refrigerant charging on air conditioner performance characteristics for three expansion devices | en |
dc.type | Thesis | en |
thesis.degree.grantor | Texas A&M University | en |
thesis.degree.name | Doctor of Philosophy | en |
thesis.degree.name | Ph. D | en |
dc.contributor.committeeMember | Degelman, L. O. | |
dc.contributor.committeeMember | Harrington, W. M. | |
dc.contributor.committeeMember | Turner, W. D. | |
dc.type.genre | dissertations | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
dc.publisher.digital | Texas A&M University. Libraries | |
dc.identifier.oclc | 23260945 |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.