Search
Now showing items 1-8 of 8
Effects of Radiant Barrier Systems on Ventilated Attics in a Hot and Humid Climate
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Results of side-by-side radiant barrier experiments using two identical 144 ft2 (nominal) test houses are presented. The test houses responded very similarly to weather variations prior to the retrofit. The temperatures ...
Program Overview: The Texas LoanSTAR Program; 1989-August 1997
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The Texas LoanSTAR mans to Save Taxes
and Resources) program was conceived as a $98.6
million capital retrofit program for building energy
efficiency. The funding source is petroleum violation
escrow funds (PVE) from the ...
Economic Evaluation of Insulation/Radiant Barrier Systems for the State of Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
This paper presents simulated performance of
insulation/radiant barrier systems under different
Texas climates. A transient heat and mass transfer
model which predicts thermal performance of
residential attics (Medina, ...
Trends in Building Energy Usage in Texas State Agencies
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1985)
In late 1983, a cost containment program was
initiated out of the governor's office directed at
the major state agencies. The Energy Management
Group at Texas A&M University provided technical
expertise in obtaining agency ...
Influence of Infrared Radiation on Attic Heat Transfer
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1985)
An experimental study concerned with different modes
of heal transfer in fibrous and cellulose insulating material
is presented. A series of experiments were conducted using
an attic simulator to determine the effects of ...
Metering and Calibration in LoanSTAR Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
End-use metering in commercial buildings often
requires installation of a large variety of transducers and data
loggers. The metering installation group in the LoanSTAR
monitoring program has the primary responsibility for ...
Program Overview: The Texas LoanSTAR Program; 1989-October 1999, A 10-Year Experience
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The Texas LoanSTAR (Loans to Save Taxes
and Resources) program was conceived as a $98.6
million capital retrofit program for building energy
efficiency. The funding source is petroleum
violation escrow funds (PVE) from the ...
Radiant Barrier Performance during the Heating Season
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Results of winter experiments conducted in Central Texas are presented. The experiments were side-by-side tests using two identical 144 ft2 houses which responded similarly to weather variations prior to any retrofits. Two ...