Cogeneration System Analysis Summary Reports for Austin State Hospital, Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1985)
Cogeneration System Analysis Summary Reports for Texas Woman’s University, Denton, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1985)
An Analysis of Efficiency Improvements in Residential Sized Heat Pumps, Final Report, May 1986
(Lawrence Berkeley Laboratory, University of California, 1985)
The objectives of this study included: (1) development of
classes of heat pumps, (2) evaluation and selection of a suitable
heat pump design model, (3) characterization of suitable baseline
heat pump designs, (4) selection ...
A Powerful Application And Troubleshooting Method For Mechanical Seals
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
Understanding the possible thermodynamic paths that a sealed fluid can follow as it goes from stuffingbox conditions, across the seal faces, and then exits to the atmosphere is a basic, but often overlooked, aspect of seal ...
Screw Pumps Of One, Two And Three Screw Design
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
Some fluid solutions utilized throughout the world have proven to be difficult to move, using “conventional” pumps. These included gas-liquid, Newtonian and non-Newtonian fluids. The screw pump, with its inherent slow ...
Critical Speed Analysis Of An Eight-Stage Centrifugal Pump
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
A critical speed and unbalance response analysis of an eight-stage centrifugal pump was performed, considering the variation of stiffness and damping coefficients with speed for both the oil firm bearings and the fluid ...
Experimental Study Of The Influence Of Backflow Control On Pump Hydraulic-Mechanical Interaction
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
A series of right-angle pump intakes, incorporating minimum axial depths and decelerating flows, has been experimentally evaluated using an air flow test procedure. Performance was measured, internal flow fields observed ...
Table of Contents for the Proceedings of the 2nd International Pump Symposium
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
Modern Cavitation Criteria For Centrifugal Pumps
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
It is well known that the performance of a rotordynamic pump deteriorates when the suction pressure is reduced below a certain value. The suction pressure is usually qualified in relation to the vapor pressure at the suction ...
Flow Patterns Causing Instabilities In The Performance Curves Of Centrifugal Pumps With Vaned Diffusers
(Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, 1985)
It is well known that backflow regimes at the impeller inlet can lead to performance instabilities for centrifugal pumps at flowrates smaller than about 65 percent of the impeller inlet design flowrate. Performance curve ...