Visit the Energy Systems Laboratory Homepage.
Operational Performance Evaluation of Boiler 9 at the TAMU Power Plant at College Station, Submitted to the Power Plant of Texas A&M University
Abstract
As part of the engineering assistance project, the ESL staff worked with operating staff at the power plant: (1) to evaluate the boiler efficiency of boiler 9 by using combustion analysis; (2) to evaluate gas and steam meters by using measured air flow rate; (3) to identify air leakage through the pre-heater by balancing 0, before and after the pre-heater; and (4) to correct air and steam metered data.
Collections
Citation
Wei, G.; Veteto, B.; Liu, M. (1996). Operational Performance Evaluation of Boiler 9 at the TAMU Power Plant at College Station, Submitted to the Power Plant of Texas A&M University. Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University. Available electronically from https : / /hdl .handle .net /1969 .1 /2162.