Centrifugal Compressor Root Cause Analysis and Case Study (Pulsation and Vibration Issues)
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
Agenda: A) Excitation forces on centrifugal compressors
B) Root cause analysis approach
C) Case study:
• Pulsations, Blade Passing Frequency, Vibration
• Pipe shell mode & acoustic resonance
• Lessons learned
Separation Seal Upgrade to overcome Repetitive Failures
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
Objectives: •Trouble shooting of Separation seal failures.
•Reference for DGS design selection at Project stage.
•Share experience with audience for improved DGS performance (in certain applications).
Mysterious Trippings of NGL Turbo Expanders on Qatargas Mega LNG Train
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
Content: •Problem Statement
•Installation Reference
•Purpose of NGL expanders
•Construction of NGL expanders
•Problem Description
•Findings & Analysis
•Problem Resolution
•Challenges Faced
•Q & A
Fluctuation of Seal Gas Supply Differential Pressure of Dry Gas Seals
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
Outline: •Problem statement
•Compressor service overview
•Description of sealing system
•Problem description
•Troubleshooting
•Findings
•Remedial Actions
•Result
•Q & A
METS2 Discussion Group 1
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
METS2 Discussion Group 2
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
INFLUENCE OF IMPELLER LEADING EDGE PROFILES ON CAVITATION AND SUCTION PERFORMANCE
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
The cavitation behavior and suction performance of a pump are
largely influenced by the geometry at the impeller eye. A
number of geometric factors at the impeller eye have an
influence on cavitation, such as, the inlet ...
Upgrading To Fully-Electric Actuation and Control of Steam Turbines
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
The use of an electric actuator for steam turbine governor valve operation is a cutting-edge technology in steam turbine control. With this design, the use of turbine oil for turbine speed control purposes is eliminated. ...
Innovative Design in Expander Wheel-Shaft Attachment Replaces Hirth Coupling for High Speed, High Temperature and High Power Applications
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
Although this Case Study is focused on an Expander-Generator unit in a geothermal application, it’s findings can be used in all turbomachinery applications where other conventional shaft-wheel attachments are causing ...
Large Steam Turbine Vibration Resonance of Pedestal and Linkage System RCA, Detail Vibration Investigation/Measurement at Site and Countermeasures
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
A Large Steam Turbine had been in operation for several years and this
turbine experienced the wear damage of governor linkage.
Then, measured the vibration velocity profile on Governor side pedestal
to identify the ...