Policy Recommendations for Establishing the LoneSTAR Monitoring and Analysis Program
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1989)
The major objectives of the Monitoring and Analysis Program (MAP) should be to: Verify energy and dollar savings of the retrofits; Reduce energy costs by identifying operational and
maintenance improvements at facilities ...
Energy Use and Design Options for Texas State Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
In 1984, the Office of Governor in the State of Texas, working through
the Energy Efficiency Division of the Public Utility Commission, instituted
a program to reduce the energy costs in state owned buildings. One
facet ...
An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
The effect of the improper charging on the performance
(capacity, EER, power consumption, SEER, and coefficient of
degradation) of a residential air conditioner during the
steady state (wet and dry coils) and cycling ...
Program Overview: The Texas LoanSTAR Program; 1989-October 1999, A 10-Year Experience
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was conceived as a $98.6 million capital retrofit program for building energy efficiency. The funding source is petroleum violation escrow funds (PVE) from the ...
Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This report presents the measured degradation in performance of a residential air conditioning
system operating under degraded conditions. Experiments were conducted using a R-22 threeton
split-type cooling system with ...
Texas LoanSTAR Monitoring and Analysis Program Draft Plan
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1989)
Major objectives of the LoanSTAR Monitoring and Analysis Program
(MAP) are to:
verify energy and dollar savings of energy conservation
retrofits in state, school and local government
buildings;
reduce energy costs by ...
Energy Systems Group Annual Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee, August 1991 (Volume I)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
The LoanSTAR program has now completed its second prototype year. This report is Volume I of a two volume set that documents the progress since the January 1991 MARC meeting. This first voume contains photocopies of the ...
An Analysis of Efficiency Improvements in Residential Sized Heat Pumps
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
The objectives of this study included: (1) development of
classes of heat pumps, (2) evaluation and selection of a suitable
heat pump design model, (3) characterization of suitable baseline
heat pump designs, (4) selection ...