Browsing Technical Reports by Title
Now showing items 37-56 of 407
-
(2002-12)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline analysis is also presented for the natural ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project at ...
-
(2007-09-21)This report presents electricity, natural gas and cooling baselines for the Thermal Plant, III Corp building, Darnall Hospital, Main Substation, West Substation, and North Substation. The baselines developed for this ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)An empirical or regression modeling approach is simple to develop and easy to use compared to use of detailed hourly simulations. Therefore, regression analysis has become a widely used tool in the determination of annual ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)DOE-2 yields hourly data on specific variables provided the user specifies the HOURLY-REPORT instruction. Analyzing the simulation results with hourly data gives a more detailed picture of how well the model is predicting ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)The University of Texas at San Antonio needs to expand their central chilled water distribution system as a result of planned additions to the campus. The current distribution system may be inadequate for the planned ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1985)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1985)
-
(2008-04)A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)
-
(2007-07-10)This report presents a study of the application of the radiant barrier / duct models to the DOE-2.1e simulation program based on the previous methods (eQuest version 3.55 and EnergyGauge version 2.42) and the comparison ...
-
Comparative Testing of the ESL's Code-Compliant Simulation Model and the FSEC's EnergyGauge Software (2007-05)This report presents a study of the comparison of the results of the ESL’s code-compliant simulation model and the FSEC’s EnergyGauge (version 2.42). Sensitivity analyses were performed by varying window-to-wall ratio ...
-
(Energy Systems Laboratory, 2014-11)The purpose of this analysis was to determine the stringency of residential provisions in the 2015 IECC when compared to the corresponding provisions in the 2012 IECC for commercial buildings in Texas. In order to perform ...
-
(Energy Systems Laboratory, 2014-08)The purpose of this analysis was to determine the stringency of residential provisions in the 2015 IECC when compared to the corresponding provisions in the 2012 IECC for residential buildings in Texas. In order to perform ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)The purpose of this report is to test the accuracy of TRNSYS simulation of Solar Pool Heating System by comparing with F-Chart program which is an authoritative tool to analyze solar system and was developed in 1970s. This ...
-
Comparison Between TRNSYS Software Simulation and F-Chart Program on Solar Domestic Hot Water System (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)This study presents the accuracy test of a TRNSYS Solar Domestic Hot Water (SDHW) System simulation. The testing is based on comparing the results with the F-Chart software. The selected system to carry out the tests was ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)This report covers the comparisons of Photovoltaic System by TRNSYS simulation and PV F-Chart program to test TRNSYS simulation accuracy. The report starts with the Photovoltaic (PV) (PV) System introduction in Section one ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)Six energy codes were compared in terms of site and source energy consumption. This comparison includes ASHRAE Standard 90.1-1989, ASHRAE Standard 90.1-1999, ASHRAE Standard 90.1-2007, ASHRAE Standard 90.1-2010, IECC 2009, ...