dc.descriptionCase Studyen
dc.description.abstractCase Study 11: National Fertilizers Limited, Nangal Unit, India had under taken the revamp of Steam Turbine of Synthesis Gas Compressor in January 2014. The plant startup, after machine revamp, was delayed by 40 days, because of various activities related to machine revamp which were not envisaged before commencement of the revamp. This paper throws light on those unforeseen jobs which lead to delay in startup and the lessons learnt to avoid such delays in future.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.languageen
dc.publisherTurbomachinery Laboratories, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposium. 2016 Proceedings.en
dc.subject.lcshTurbomachinesen
dc.subject.lcshPumping machineryen
dc.titleRevamp of Steam Turbine for Synthesis Gas Compressor at NFL Nangalen