    • Kumar, Arun; Sabharwal, Mohit (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      During the commissioning of centrifugal machines (Compressors, steam turbines, pumps, fans etc.), a lack of flushing, inspection and ignorance of critical areas & procedures can lead to major problems, damage, and serious ...
    • Huebner, Michael; Appleman, Kent (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Dual mechanical seals represent one of the most common approaches to improving seal reliability and reducing process emissions. While the presence of the pressurized barrier fluid provides significant benefits, the challenge ...
    • Cloud, C. Hunter; Kocur, John (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Tutorial 18: Understanding the lateral rotordynamic behavior is critical in determining the reliability/operability of rotating equipment. Whether examining a centrifugal pump or compressor, steam or gas turbine, motor or ...
    • Ponnanna, Bopanna Pudiyokada; Yu, John J.; Drygin, Sergey; Peton, Nicolas; Schluter, Steven (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2022)
      This case study outlines how structural vibration was resolved using two different technologies and highlighting secondary issues that can arise due to continued vibration because of structural resonance. Continued high ...
    • Vázquez, José A.; Cloud, C. Hunter; Eizember, Robert J. (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Tutorial 6: Experimental modal analysis and operating deflection shapes (ODS) are powerful tools in vibration analysis and machinery troubleshooting. However, the machinery plant engineer often doesn’t believe such techniques ...
    • Blair, Barry J.; Kim, Jong; dos Santos, Marcio Felipe (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Case Study 22: Over a 13‐year span, a major South American oil company’s maintenance department fought high vibrations in three gas reinjection compressor trains. To reduce the chances of machine trips, technicians field ...
    • Ganesan, Vijay; Busse, Stephan; Demmig, Sven (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Lecture 3: Variable-frequency drives (VFDs) are being increasingly employed in oil and gas (O&G) applications due to their better efficiency, reliability and process control when compared to conventional drives. In comparison ...
    • San Andrés, Luis; Jeung, Sung-hwa; Den, Sean; Savela, Gregory (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Lecture 15: Squeeze Film Dampers (SFDs) are effective means to ameliorate rotor vibration amplitudes and to suppress instabilities in rotor-bearing systems. A SFD is not an off-the-shelf mechanical element but tailored to ...
    • Baumann, Urs (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Tutorial 2: In many cases it is necessary to judge the stability behavior of a specific compressor. This might be the OEM checking the feasibility of a proposed compressor layout or it might be the user judging one of his ...
    • Ahmed Bin Najeeb, Ovais; Childs, Dara (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Annular seals are non-contacting mechanical elements designed to reduce leakage between two areas of differing pressures such as between two impeller stages in a pump. Circumferential fluid rotation inside the annular ...
    • Jun, Ker Pin; Sing, Ng Wei (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2022)
      The governor actuator for a steam turbine was observed to be hunting and failed to maintain stable operating speed. The steam turbine is used to drive a centrifugal compressor for H2 service in a recycle loop. The extent ...
    • Bhat, Vasanth; Suthan, Thangavel (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      The Wet Gas compressor is one of the most critical assets in a FCCU/RCCU of a oil refinery. The back pressure steam turbine driver of this compressor faced two failures in the main valve stem of the steam inlet valve. ...
    • Ikeno, Kyoichi; Katagake, Makoto; Hata, Satoshi (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Case Study 3
    • Josefczyk , Ronald; Kumar, Arun (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Suggested Topics: • Overhaul intervals • Maintenance practices Solid particle erosion • Contract versus in-house maintenance Mechanical driver turbine issues - design et al • Steam path repairs • Turbine casing and alignment ...
    • Peton, Nicolas; Drygin, Sergey (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      This case study is designed to outline how the high vibration issue was successfully diagnosed, the root cause for the high vibration found and correction actions recommended. The source of mentioned high vibration - sub ...
    • Tipton, Anthony (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Case Study 1: Stress corrosion cracking is known to be a function of stress, material and environment. However, a fourth variable that is often overlooked is operating time. Maintaining steam chemistry within OEM and ...
    • Giancotti, Marco; Fattori, Stefano; Biondi, Roberto; Margiotta, Alessio (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Lecture 9: The traditional onshore installation of heavy duty gas turbine generator trains, especially for power >80MW, is stick built on heavy and rigid concrete block foundation. The challenge of modularization is that ...
    • Neilson, Bryce (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      While pitot tube pumps have been commercially available since 1970 little is known and less is published about their internal operation and design principles especially when operating off design. This paper is a culmination ...
    • Gilarranz, José; Maier, William; Baumann, Urs; Barratt, Richard; Bigi, Manuele (Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)
      Tutorial 22: The use of Subsea gas compression technology for subsea re-injection and/or gas transport boosting represents a new and exciting application for rotating equipment, which will allow new gas/condensate field ...
    • Hirata, Daisuke; Nagai, Naoyuki; Higashimori, Hirotaka; Shoji, Yoshiaki (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Subsynchronous shaft vibration was observed in an integrally geared expander-compressor when the machine was operated with a partial load in the course of plant start up. The root cause of the synchronous shaft vibration ...