Search
Now showing items 1-10 of 29
Early Detection Of Rotating Stall Phenomenon In Centrifugal Compressors By Means Of ASME PTC 10 Type 2 Test
(Texas A&M University. Turbomachinery Laboratories, 2012)
A centrifugal compressor presenting rotating stall can exhibit many problems, as limitation on its operational range, high level of subsynchronous vibrations, reduced efficiency and premature bearing wear. There are many ...
World's First 10,000 PSI Sour Gas Injection Compressor
(Texas A&M University. Turbomachinery Laboratories, 2008)
This paper traces the development of the original sour gas injection (SGI) concept, the methodology used for managing risks, detailed design and testing of compression train components, compressor train shop string tests, ...
Subsea Centrifugal Compressor Development - Breakthrough Technology For Oil And Gas Offshore Production.
(Texas A&M University. Turbomachinery Laboratories, 2002)
As the offshore market faces deepwater production challenges, the oil and gas industry is investing in new technologies to bring down the costs in the subsea fields exploitation. A breakthrough technology solution is the ...
Discussion Group T17 On Advanced Topics in Centrifugal Compressor Design
(Texas A&M University. Turbomachinery Laboratories, 2011)
Prediction and Mitigation of High Radial Vibrations During Hot Restart of Centrifugal Compressors
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2017)
Discussion Group T11: Dry Gas Seals for Compressors
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2015)
Operational modal analysis application for the measure of logarithm decrement in centrifugal compressor
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2015)
The results of a stability test on a centrifugal compressor during the full load test of the entire compression train are presented. A Magnetic Exciter was installed at the shaft end in order to excite the first lateral ...
Improving LNG Facility Reliability and Operability Via OEM Integrated Compressor Controls
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2017)
Modeling Of Rotor Bow During Hot Restart In Centrifugal Compressors
(Texas A&M University. Turbomachinery Laboratories, 2010)
Rotor bow during hot restart is a common cause of high vibrations in turbomachinery. It may occur after the shutdown of a machine operating under load, if the rotor is left cooling in standstill condition (no turning gear) ...
Discussion Group T09: Dry Gas Seals for Compressors
(Turbomachinery Laboratories, Texas A&M Engineering Experiment Station, 2016)