Search
Now showing items 31-40 of 44
Cool Storage Applications in the Texas LoanSTAR Program: Overview and Preliminary Results
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Cool Storage Systems (CSS) are becoming a popular demand side management tool for utilities because that helps them avoid costly plant expansions and reduces summer-time peak electricity demand. This paper presents an ...
Texas LoanSTAR Monitoring and Analysis Program Progress Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1990)
Eleven audit reports have been accepted by the review staff at Texas A&M
University. These eleven reports cover 3.8 million square feet of building space and two
street-lighting projects. One engineer has been employed ...
Texas LoanSTAR Monitoring and Analysis Program: Monitoring Equipment Installation Manual (October 1994)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
The Texas LoanSTAR (Loans to Save Taxes and Resources) Program is a $98.6 million revolving loan fund to finance energy conservation retrofits in Texas government buildings. The loans are repaid through energy cost savings ...
Thermal Energy Measurement with Tangential Paddlewheel Flow Meters: Summary of Experimental Results and in-situ Diagnostics
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Recently third-party financing has become a popular mechanism for funding energy conservation retrofits in commercial/institutional buildings. Although many successful projects have been heralded by the press quite a few ...
Instructions for "The Great Energy Predictor Shootout II: Measuring Retrofit Energy Savings"
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Based on the overwhelming response to the first Building Energy Predictor Shootout a second predictor Shootout has been developed to again compare how well different empirical models predict building energy data from several ...
An Overview of Measured Energy Retrofit Savings Methodologies Developed in the Texas LoanSTAR Program
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Development of methodologies to determine energy retrofit savings in commercial buildings (institutional buildings, schools, hospitals, offices, county and state buildings,...) has been the object of active research during ...
Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Several state owned buildings with dual-duct constant volume (DDCV) systems have
been retrofitted with energy efficient variable air volume systems (VAV) as part of the
Texas LoanSTAR Program. One method of determining ...
Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Preliminary Engineering Survey, USDOE Forrestal and Germantown Facility, Summary Report, USDOE Office of Conservation and Energy
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
The purpose of this preliminary engineering survey of the USDOE Forrestal and Germantown
facilities is to determine whether existing EMCSs can be used for monitoring energy retrofits, and in
the case where this is not ...
Potential Operation and Maintenance (O&M) Savings in the John Sealy South Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The LoanSTAR Monitoring and Analysis Group was requested by UTMB to investigate O&M measures in their five LoanSTAR program buildings. This report describes the suggested O&M measures in John Sealy South Building, an ...
Internet Polling Development Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This is the final report which documents the development of Internet-based data logger polling. The project consists of two main tasks: the development of automated polling procedures that can be launched remotely with no ...