Case History - Energy Reduction at the Abilene Texas Instruments Plant
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1983)
In 1977, TI purchased a 158,000 SF, single story building which was designed and built prior to the 1973 energy crises and, hence, has no built in energy conservation.
This paper addresses the principal retrofit measures ...
Energy Saving Pumping Systems in Chemical Plant Design
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1980)
The current cost of electrical power is translated into an annualized value to be used for economic considerations in the selection of pumping equipment. Motor sizing guidelines are suggested to permit electric motors to ...
Electrofiltration: An Energy Efficient Alternative in Solid-Liquid Separations
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
Electrofiltration has established itself as an energy efficient unit operation in ultrafine particle dewatering. The Dorr-Oliver Electrofilter combines vacuum cake filtration with electrophoresis and electroosmosis. This ...
Efficient Energy Utilization in the Industrial Sector - Case Studies
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
The need for more efficient use of the world's energy resources has become one of the major concerns of technology today. Over the past 50 years, during which our population has doubled, our requirements for energy has ...
Identifying Savings Opportunities
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1993-03)
In this paper, guidelines for identifying energy savings opportunities in industrial plants are discussed. The analytical approach used in this discussion stems from the fundamental principle that the total energy into and ...
A Free Cooling Based Chilled Water System at Kingston
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
In efforts to reduce operating costs, the IBM site at Kingston, New York incorporated the energy saving concept of 'free cooling' (direct cooling of chilled water with condenser water) with the expansion of the site chilled ...
Sandjet- A New Alternative for Cleaning Furnace Tubes
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1981)
Energy management in modern refineries is becoming more difficult as the real cost of in-house and purchased fuel escalates and the quality of feed stocks decreases. Furnace tube maintenance has been made more complex by ...
Insulation of Pipe Bends Improves Efficiency of Hot Oil Furnaces
(Energy Systems Laboratory (http://esl.tamu.edu), 1999-05)
Thermodynamic analyses of processes indicated low furnace efficiencies on certain hot oil furnaces. Further investigation, which included Infrared (IR) thermography testing of several furnaces, identified extremely hot ...
ESL Monthly Energy Consumption Report (MECR) Production Manual
(Energy Systems Laboratory (http://esl.tamu.edu), 2005-03)
Energy Savings Report For Dallas County, July 2000 – June 2001
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...