Show simple item record

dc.creatorPargmann, Amber Rae
dc.date.accessioned2012-06-07T23:07:30Z
dc.date.available2012-06-07T23:07:30Z
dc.date.created2001
dc.date.issued2001
dc.identifier.urihttps://hdl.handle.net/1969.1/ETD-TAMU-2001-THESIS-P352
dc.descriptionDue to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item.en
dc.descriptionIncludes bibliographical references (leaves 62-63).en
dc.descriptionIssued also on microfiche from Lange Micrographics.en
dc.description.abstractThe EPA revised the National Ambient Air Quality Standard (NAAQS) in 1997 to include a standard for fine particulates (PM₂₅̣), and was unanimously upheld by the US Supreme Court in February of 2001. The long-term standard was set at 15 mg/scm, and the short-term standard was set at 65 mg/scm. A PM₂₅̣ sampler was developed for the Federal Reference Method shortly after the revision of the NAAQS, and was mandated "by design" rather than "by performance," due to the limited available performance data. Methods for determining PM₂₅̣ concentrations in the ambient air are designated as either reference or equivalent methods. Accuracy of the subject method is determined by collocating the subject method with a FRM sampler in an urban environment. However, these samplers are not tested in the presence of agriculture dusts, which have a larger mass median diameter (MMD) than urban dusts. This research addressed the performance characteristics of PM₂₅̣ samplers in the presence of agricultural dusts. Tests in a controlled laboratory environment were performed on three PM₂₅̣ samplers: a FRM sampler with Wells Impactor Ninety-Six, a FRM sampler with Sharp-Cut Cyclone, and a High-Volume PM₂₅̣ Sampler. Three dusts were used for sampling: alumina, corn starch, and wheat flour. Ten replications were performed for each sampler in each dust for a total of ninety replications. Performance characteristics, by way of fractional efficiency curves, could not be determined for all of the samplers. The cut-point and slope for the FRM sampler with WINS were found to be 1.95 ± 0.10 [u]m and 1.31 ± 0.04, respectively. Concentration measurements for the test samplers were compared to the "true" PM₂₅̣ concentrations, determined by multiplying the fraction less than 10 [u]m from the Coulter Counter PSD times the TSP concentration. The results showed the percent error of the PM₂₅̣ samplers increased with the MMD of the dust sampled. The hypothesis was that the PM₂₅̣ samplers used to monitor PM₂₅̣ concentrations in the ambient air will not accurately perform in an agricultural environment. It was concluded that the use of these PM₂₅̣ samplers would result in unfair regulation of the agricultural industry.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.subjectagricultural engineering.en
dc.subjectMajor agricultural engineering.en
dc.titlePerformance characteristics of PM₂₅̣ samplers in the presence of agricultural dustsen
dc.typeThesisen
thesis.degree.disciplineagricultural engineeringen
thesis.degree.nameM.S.en
thesis.degree.levelMastersen
dc.type.genrethesisen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.