Show simple item record

dc.creatorWood-Zika, Annmarie Ruth
dc.date.accessioned2012-06-07T22:51:09Z
dc.date.available2012-06-07T22:51:09Z
dc.date.created1997
dc.date.issued1997
dc.identifier.urihttps://hdl.handle.net/1969.1/ETD-TAMU-1997-THESIS-W555
dc.descriptionDue to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item.en
dc.descriptionIncludes bibliographical references.en
dc.descriptionIssued also on microfiche from Lange Micrographics.en
dc.description.abstractNeutron fluence-to-dose equivalent conversion factors are calculated for three types of finger and wrist extremity phantoms: (1) the polymethyl methacrylate models specified by the U.S. Department of Energy Laboratory Accreditation Program for Personnel Dosimetry Systems (DOELAP); (2) the tissue-and-bone phantoms suggested by Pacific Northwest National Laboratory; and (3) the Radiology Support Devices (RSD) Inc. RS-122T an-n/shoulder phantom. Extremity factors are determined at shallow surface and bone levels for bare, D20moderated and polyethylene moderated 112Cf. The DOELAP free-field calibration geometry and a realistic glovebox scenario are simulated using a Monte Carlo neutron and photon transport code. Calculated DOELAP and RSD extremity fluence-to-dose equivalent conversion factors for the free-field calibration geometry are 1 to 9 percent lower than the calculated whole-body conversion factor. The tissue-and-bone phantoms exhibit conversion factors 1 to 10 percent greater than the whole-body factor. Glovebox fluence-to-dose equivalent conversion factors range from 12 percent less than to 128 percent greater than calculated free-field whole-body conversion factors. A preliminary evaluation of the application of the calculated fluence-to-dose equivalent conversion factors to Los Alamos National Laboratory extremity dosimeter correction factors is performed.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.subjecthealth physics.en
dc.subjectMajor health physics.en
dc.titleCalculation of extremity neutron fluence-to-dose equivalent conversion factorsen
dc.typeThesisen
thesis.degree.disciplinehealth physicsen
thesis.degree.nameM.S.en
thesis.degree.levelMastersen
dc.type.genrethesisen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen