Show simple item record

Visit the Energy Systems Laboratory Homepage.

dc.creatorGoodman, M. A.
dc.date.accessioned2011-04-11T15:35:18Z
dc.date.available2011-04-11T15:35:18Z
dc.date.issued1981
dc.identifier.otherESL-IE-81-04-128
dc.identifier.urihttps://hdl.handle.net/1969.1/94390
dc.description.abstractUltrasonic emissions are utilized as a method for locating sources of energy waste. Included in the discussions will be a description of the unique 'Tone Test' for locating faulty seals and gaskets as well as leaking heat exchanger tubes. Quick check methods of leak location in steam and compressed air/gas systems will also be presented.en
dc.publisherEnergy Systems Laboratory (http://esl.tamu.edu)
dc.publisherTexas A&M University (http://www.tamu.edu)
dc.subjectUltrasonic Emissions Detectionen
dc.subject'Tone Test'en
dc.subjectHeat Exchanger Tubesen
dc.subjectLeaking Seals and Gasketsen
dc.titleUltrasonic Emissions Warn of Energy Lossen
dc.contributor.sponsorU. E. Systems, Inc.


This item appears in the following Collection(s)

Show simple item record