dc.description.abstractA Georgia-Pacific plywood plant located in Madison, Georgia recently decided to insulate their steam lines for energy conservation, improved process efficiency and personnel protection. The goal of the project was to eliminate dependency on purchased fuel. Georgia-Pacific realized immediate and significant results and reduced fuel cost by about one third over a one year period.en