Texas A&M University LibrariesTexas A&M University LibrariesTexas A&M University Libraries
    • Help
    • Login
    OAKTrust
    View Item 
    •   OAKTrust Home
    • Colleges and Schools
    • Office of Graduate and Professional Studies
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    • View Item
    •   OAKTrust Home
    • Colleges and Schools
    • Office of Graduate and Professional Studies
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design of a wall-less proportional counter for microdosimetry in nanometer dimensions

    Thumbnail
    View/Open
    etd-tamu-2005A-HLPH-RAYADUR.pdf (867.6Kb)
    Date
    2006-08-16
    Author
    Rayadurgam, Sripriya
    Metadata
    Show full item record
    Abstract
    Knowledge of energy deposition in biological cells at nanometer dimensions is essential to understand the biological effects of radiation. This work has resulted in the development of a practical tool to study such energy deposition experimentally, at nanometer dimensions. The main contribution of this research is the design of a cylindrical wall-less proportional counter of 1mm height by 1mm diameter. A wall-less detector (also called grid-walled detector) overcomes the so-called “wall effect”, an experimental artifact that introduces distortions in the radiation energy measurements. An important feature of this detector that distinguishes it from other detectors is its modular design. This allows the detector to be repaired or modified, when necessary, without having to completely disassemble it. Novel design techniques were adopted resulting in a functional detector that can simulate cellular sites as small as 10 nanometers, approximately the size of many molecules in the cell. The detector was tested with a 1 microcurie sealed Am-241 source, which primarily emits monoenergetic alpha particles of energy 5.57 MeV. Microdosimetric spectra analysis for alpha particles and its delta rays from Am-241 were performed for simulated site sizes ranging from 500nm to 10nm. Initial studies to validate the detector design have confirmed good detector performance. We believe this work will serve as a vital platform for bridging the experimentally measured energy spectra to the biological effects of alpha and delta radiations.
    URI
    http://hdl.handle.net/1969.1/3801
    Subject
    wall-less
    nanometer
    Collections
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    Citation
    Rayadurgam, Sripriya (2005). Design of a wall-less proportional counter for microdosimetry in nanometer dimensions. Master's thesis, Texas A&M University. Texas A&M University. Available electronically from http : / /hdl .handle .net /1969 .1 /3801.

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Advanced Search

    Browse

    All of OAKTrustCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDepartmentThis CollectionBy Issue DateAuthorsTitlesSubjectsDepartment

    My Account

    LoginRegister

    Statistics

    View Usage Statistics
    Help and Documentation

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV