Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Single-Family Residential Buildings in Houston Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
This paper presents information about the energy saving potential for single-family residential buildings in Houston, Texas that are designed to be 15% above code. The energy efficient measures discussed in this paper were ...
Cost-Effective Energy Efficiency Measures for 15% Above 2009 IECC Code-Compliant House for Residential Buildings in TX
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
Cost-Effective Energy Efficiency Measures for 15% Above 2009 IECC Code-Compliant House for Residential Buildings in TX
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
Energy Savings and Persisitence From an Energy Services Performance Contract at an Army Base
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
Statewide Electricity and Demand Capacity Savings from the Implementation of IECC Code in Texas: Analysis for Single-Family Residences
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
Going Beyond a Resnet Certification for Code-Compliant Simulations: A Sensitivity Analysis of Detailed Results of Three RESNET-Certified, Code-Compliant Residential Simulation Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
In many states building code officials rely on certified, code-compliant simulations to determine whether or not a residence satisfies the energy code requirements using a performance-path analysis. In the United States, ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Multifamily Residential Buildings in Houston Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
This paper presents results from an analysis of the energy saving potential for multifamily residential buildings in Houston. In this analysis, the energy efficient measures were proposed by the building officials with the ...
Continuous Commissioning® of the Dallas/Fort Worth International Airport
(Energy System Laboratory (http://esl.tamu.edu), 2008-10)
The DFW International Airport is one of the largest and busiest airports in the world. Located in North Texas, squarely between the cities of Dallas and Fort Worth, the DFW Airport not only serves a huge population in ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and Its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007-12)
Recently Texas Legislature required adding 5,880 MW of generating capacity from renewable energy technologies by 2015, and 500 MW from non-wind renewables. This legislation also required the Public Utility Commission (PUC) ...
Continuous Commissioning: A Valuable Partner to Retrofit Projects
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2001)
Continuous Commissioning (CC) or HVAC system
optimization is not only a valuable stand-alone energy
saving measure for commercial buildings, but it is also
an important escort solution to retrofit projects. Energy
retrofit ...