LoanSTAR Monitoring and Analysis Program: Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
During the Fall of 1992 a comprehensive survey was conducted on
eight buildings at the State Capitol Complex to determine potential
operations and maintenance (O&M) savings opportunities. A verbal
report of the findings ...
Potential Operation and Maintenance (O&M) Savings in the Basic Science Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential energy savings due to optimizing the Heating, Ventilation and Air Conditioning (HVAC) operation schedule in the Basic Science Building at University of Texas ...
Summary of UTMB O&M Project: Energy Conservation Potential in Five Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report is a summary of five reports (references 1 to 5) which provided detailed
descriptions of an O&M investigation of the following five buildings on the UTMB
campus: 1) John Sealy North Building(JSN); 2) Clinical ...
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Air static pressure must be maintained at a
certain level leaving the air-handing unit (AHU) to
force a suitable amount of air through the terminal
boxes. However, an excessive static pressure level is
often used due to ( ...
An Advanced Economizer Controller for Dual Duct Air Handling Systems - with a Case Application
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heating penalty is expected when economizers
are applied to dual-duct air handling systems.
The heating penalty can even be higher than the
cooling savings when the hot air flow is higher
than the cold air flow. To avoid ...
A Prediction of Energy Savings Resulting from Building Infiltration Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heat transfer through building walls
consists of three main components:
conduction heat transfer, solar gain and
infiltration heat transfer. An interaction
among these three heat transfer
components alters the effective ...
The Measured Energy Impact of Infiltration in an Outdoor Test Cell
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The energy consumption calculation of house envelopes assumes that conduction heat loss is independent on air infiltration heat loss, and that energy consumption is the sum of these losses. Anderlind [1985], Liu [1987], ...
Preliminary Study of O&M Opportunities at the University of Texas Medical Branch at Galveston, Submitted to The Energy Management and Operations Department at UTMB Galveston
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
At the request of the Energy Management and Operations Department at the University of Texas Medical Branch at Galveston, the Energy Systems Laboratory at the Texas A&M University performed the preliminary study of O&M ...
Potential Operation and Maintenance (O&M) Savings in the John Sealy North Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The LoanSTAR Monitoring and Analysis Group, Energy Systems Laboratory at Texas A&M University, was requested by University of Texas Medical Branch at Galveston to investigate O&M measures in their five LoanSTAR program ...
Variable Speed Drive (VSD) Applications in Dual-Duct Constant Volume Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Models have been developed for static pressure
and potential supply fan energy savings by using
variable speed drive (VSD) in dual-duct constant
volume systems. Experiments have been performed
using a full size dual-duct ...