Reduce Building Energy Consumption by Improving the Supply Air Temperature Schedule and Recommissioning the Terminal Boxes, Submitted to the Energy Management and Operations Division at the M.D. Anderson Cancer Center
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
At the request of the Energy Management and Operations Department at M.D. Anderson Cancer Center, the Energy Systems Laboratory of Texas A&M University performed a study of optimizing the HVAC operation at its Basic Research ...
Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance (O&M)
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
In most chiller and boiler central plants, the
energy management and control systems (EMCS)
monitor and record key operation parameters and
energy production continuously. A method was
developed to identify potential O&M ...
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Air static pressure must be maintained at a
certain level leaving the air-handing unit (AHU) to
force a suitable amount of air through the terminal
boxes. However, an excessive static pressure level is
often used due to ( ...
Preliminary Study of O&M Opportunities at the University of Texas Medical Branch at Galveston, Submitted to The Energy Management and Operations Department at UTMB Galveston
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
At the request of the Energy Management and Operations Department at the University of Texas Medical Branch at Galveston, the Energy Systems Laboratory at the Texas A&M University performed the preliminary study of O&M ...
Terminal Box Airflow Reset: An Effective Operation and Control Strategy for Comfort Improvement and Energy Conservation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
A new terminal box operation and control
strategy, airflow reset, is developed to improve
building comfort and energy efficiency during
unoccupied and lightly occupied hours. The airflow
reset lowers the minimum airflow ...
A Novel Procedure to Determine Optimal Air Static Pressure Set-points and Reset Schedules in VAV Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Air static pressure set-point or schedule for VAV
AHLJ systems is one of the most crucial
operational parameters for satisfy lug the building
load, maintaining the room comfort level and
saving energy costs. This paper ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Optimization Control Strategies for HVAC Terminal Boxes
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The HVAC terminal boxes are one of the
major building HVAC components. They
directly impact the building room comfort
conditions and the energy costs. How to operate
the box in a highly energy efficient way and
maintain ...
A Simple and Quick Chilled Water Loop Balancing for Variable Flow System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
For many modem buildings, the chilled water
loops and risers are equipped with variable speed
pumping systems. How to quickly balance the
loop or riser to satisfy the cooling requirement
and reduce energy consumption is a ...