Operational Performance Evaluation of Boiler 9 at the TAMU Power Plant at College Station, Submitted to the Power Plant of Texas A&M University
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1996)
As part of the engineering assistance project, the ESL staff worked with operating staff at the power plant: (1) to evaluate the boiler efficiency of boiler 9 by using combustion analysis; (2) to evaluate gas and steam ...
Optimize the Supply Air Temperature Reset Schedule for a Single-Duct VAV System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The supply air temperature for a single-duct
variable air volume (VAV) system is usually set as a
constant. To minimize the simultaneous cooling and
heating, this supply temperature is often reset based
on either return ...
Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The supply air temperature set point for a singleduct
constant air volume air handling unit (AHU)
system is often reset based on either return air
temperature or outside air temperature in order to
reduce simultaneous ...
Development of a Procedure for the Predictive Control Strategy of a Chilled Water Storage System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Thermal energy storage systems store the
thermal energy produced by the chiller plant in
periods of off-peak electrical demand or when
cheaper electricity is available. The stored thermal
energy is then withdrawn from the ...
Optimization Measures for Sporting and Special Event Facilities: Design and Operation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Reducing unnecessary building energy costs
is becoming more of a priority. Rising fuel
prices and a global emphasis on energy
efficiency are key contributing factors. This
push towards energy efficiency certainly applies
to ...
Signatures of Heating and Cooling Energy Consumption for Typical AHUs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
An analysis is performed to investigate the
signatures of different parameters on the heating
and cooling energy consumption of typical air
handling units (AHUs). The results are presented
in graphic format. HVAC simulation ...