    Automatic flush valve performance (gallons per flush) measured from fixtures in a mixed-use classroom/office building at Texas A&M University

    Thumbnail
    View/Open
    etd-tamu-2005A-COMG-Lertban.pdf (1.292Mb)
    Date
    2005-08-29
    Author
    Lertbannaphong, Salilla
    Metadata
    Show full item record
    Abstract
    Since water-use characteristics and the new technology of plumbing fixtures have changed, it is significant to educate a facility manager in the characteristics of these systems. Also, it is necessary to provide a better understanding of parameters that may determine the suitability of retrofitting plumbing fixtures. The 1992 Energy Policy Acts enforces 1.6-gallon per flush (gpf) for a toilet and 1.0 gpf for a urinal. In response to the regulation, the purpose of this research is to measure automatic flush valve performance (gpf) of fixtures in a mixed use classroom building at Texas A&M University. Water consumption (gpf) among three types of fixtures; low-consumption manual, old optic automatic and improved optic automatic systems are measured by using a magnetic water flow meter. The data in the study were analyzed to determine compliance with plumbing standards and to compare the average water volume per flush cycle of toilets in the men??s and women??s restrooms. Finally, the results of the data show that retrofitting the old optic automatic with the improved optic automatic system resulted in water savings of about 15.80% in toilets, and urinals.
    URI
    http://hdl.handle.net/1969.1/2426
    Subject
    Automatic Flush Valve
    Gallon per Flush
    Collections
    • Electronic Theses, Dissertations, and Records of Study (2002– )
    Citation
    Lertbannaphong, Salilla (2006). Automatic flush valve performance (gallons per flush) measured from fixtures in a mixed-use classroom/office building at Texas A&M University. Master's thesis, Texas A&M University. Texas A&M University. Available electronically from http : / /hdl .handle .net /1969 .1 /2426.

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Advanced Search

    Browse

    All of OAKTrustCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDepartmentThis CollectionBy Issue DateAuthorsTitlesSubjectsDepartment

    My Account

    LoginRegister

    Statistics

    View Usage Statistics
    Help and Documentation

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV