Browsing Technical Reports by Title
Now showing items 270-289 of 407
-
(2008-11)This report presents detailed information about the analysis that was performed to calculate the energy saving potential for residential buildings in Houston. In this analysis the energy efficient measures were proposed ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-11)In the 79th Legislature (2005) the Energy Systems Laboratory was required to develop three alternative methods for achieving 15% above-code energy savings in new residential, commercial and industrial construction. The ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1988)Over 100 tests of potential design modifications for the cell light fixtures used by the Texas Department of Corrections have been conducted. As a result of these tests, the following recommendations are made: 1. Turn ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1995)At the request of the Energy Management and Operations Department at M.D. Anderson Cancer Center, the Energy Systems Laboratory of Texas A&M University performed a study of optimizing the HVAC operation at its Basic Research ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1984)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)This reports summarizes the electricity, natural gas and NOx emissions reductions from retrofit measures reported as part of the AACOG emissions reduction effort. The electricity and natural gas savings were collected by ...
-
(Energy Systems Laboratory, Texas A&M University., 2011-09)
-
(2009-03)The Southern Energy Efficiency Center (SEEC) was established to substantially increase the deployment of high-performance “beyond-code” buildings across the southern region of the U.S. It is funded by the U.S. Department ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The director of Energy Management & Controls and staff at Tarleton State University (TSU) do a very good job of maintaining TSU and keeping expenses down. They have metering installed in many buildings and track the campus ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at Prairie View A&M University (PVAMU) do a good job of maintaining PVAMU facilities and keeping expenses down. During our visit, however, we were able to identify several opportunities ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at Texas A&M International University at Laredo do a very good job of maintaining TAMIU facilities. During our visit, however, we were able to identify several opportunities for improving ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at Texas A&M University-Corpus Christi (TAMUCC) do a very good job of maintaining TAMU-CC and keeping expenses down. During our visit, however, we were able to identify several ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at Texas A&M University at Galveston (TAMU-G) do a very good job of maintaining TAMU-G facilities and keeping expenses down. During our visit, however, we were able to identify several ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The energy costs for TAMU-Commerce are very high when compared to most of the other universities in the TAMUs. For example, the price of $1.6 per square foot per year for utilities is nearly twice that of the Kingsville ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at Texas A&M University - Kingsville (TAMU-K) do a very good job of maintaining TAMU-K facilities and keeping expenses down. During our visit, however, we were able to identify several ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director at Texas A&M University - Texarkana (TAMU-T) does a very good job of maintaining TAMU-T facilities and keeping expenses down. During our visit, however, we were able to identify several opportunities ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)The physical plant director and staff at West Texas A&M University (WTAMU) do a very good job of maintaining WTAMU facilities and keeping expenses down. During our visit, however, we were able to identify several opportunities ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)This report was created for the National Science Foundation-Physical Building Information Modeling (NSF-PBIM) project. This report describes the analysis of a solar office building using the following software: the legacy ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)The Energy Systems Laboratory (ESL) at the Texas Engineering Experiment Station, Texas A&M University System was contacted by Mr. Peter Bella of the Alamo Area Council of Governments (AACOG) to help document large-scale, ...
-
(Energy Systems Laboratory, 2008-12)