Search
Now showing items 11-20 of 1531
Energy Efficiency / Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. II – Technical ReportAnnual Report to the Texas Commission on Environmental Quality, Sept. 2003 to Aug. 2004
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its third annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
Energy Savings Assessment for the Robert E. Johnson State Office Building in Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
U.S. businesses and institutions spend an
estimated $175 billion per year for energy. Of that, the
fraction under performance contracts and energy
service agreements is currently growing, aided by
cheaper monitoring ...
Measured Cooling Performance of Two-story Homes in Dallas, Texas; Insulated Concrete Form Versus Frame Construction
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Four occupied homes near Dallas, Texas were
monitored to compare heating and cooling energy
use. Two homes were built with typical wood frame
construction, the other two with insulated concrete
form (ICF) construction.
Remote ...
A Model for Evaluation of Life-Cycle Energy Savings of Occupancy Sensors for Control of Lighting and Ventilation in Office Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes ...
Continuous Commissioning® of a Modern Central Utility Plant
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Effect of Photocatalytic Coatings on the Weathering of Elastomeric Roofing Membrane
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Direct Expansion Air Conditioning System Selection for Hot & Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
This paper discusses some of the difficulties of
selecting direct expansion (DX) air conditioning
systems to dehumidify conditioned spaces in hot &
humid climates. It is a common opinion among
designers that concerns of ...
Corrosion of Aluminum-fin, Copper-tube Heat Exchange Coils
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Over the past several years the HVAC industry
has experienced a large increase in instances of leaks
in the central portion of aluminum-finned, coppertube
heat exchange coils. These leaks are
characterized as being very ...
Energy Efficiency / Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. I – Summary ReportAnnual Report to the Texas Commission on Environmental Quality, Sept. 2003 to Aug. 2004
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its third annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
NOx Emissions Reductions from Implementation of the 2000 IECC/IRC Conservation Code to Residential Construction in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
Four areas in Texas have been designated by
the United States Environmental Protection
Agency (EPA) as non-attainment areas because
ozone levels exceed the National Ambient Air
Quality Standard (NAAQS) maximum allowable
limits. ...