Methodology for Residential Building Energy Simulations Implemented in the International Code Compliance Calculator (IC3)
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
Since 2001, Texas has been proactive in initiating clean air and energy efficiency in building policies. The Texas Emissions Reduction Plan legislation (SB 5, 77TH Leg., 2001) mandates statewide adoption of energy codes, ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Single-Family Buildings in Houston Texas
(2008-11)
This report presents detailed information about the analysis that was performed to calculate the energy saving potential for residential buildings in Houston. In this analysis the energy efficient measures were proposed ...
Recommendations for 15% Above-Code Energy-Efficiency Measures for Commercial Office Buildings
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
This paper presents an overview of the recommendations for achieving 15% above code energy performance for commercial office buildings complying with ASHRAE Standard 90.1-1999. To accomplish the 15% annual energy consumption ...
Evalutaion of Energy Efficiency Measures for K-12
(Energy Systems Laboratory, 2011)
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Preliminary Report: Integrated NOx Emissions Savings from EE/RE Programs Statewide
(2008-08-29)
The Energy Systems Laboratory (ESL), at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Volume I-Summary Report, Annual Report to the Texas Commission on Environmental Quality, January 2009-December 2009
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Volume III- Technical Appendix, Annual Report to the Texas Commission on Environmental Quality, January 2009 – December 2009
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Comparison of ASHRAE Standard 90.1, 189.1 and IECC Codes for Large Office Buildings in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
Six energy codes were compared in terms of annual site and source energy consumption. This comparison includes ASHRAE Standard 90.1-1989, ASHRAE Standard 90.1-1999, ASHRAE Standard 90.1-2007, ASHRAE Standard 90.1-2010, ...
Cost-Effective Energy Efficiency Measures for Above Code(ASHRAE 90.1-2001 and 2007) Small Restaurant Buildings in the City of Arlington