Joint-Frequency Bins versus Conventional Bin Weather Data in Analysis of HVAC System Operation
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
Often in simplified energy analysis the use of bin weather data is employed for a more time efficient and better organized analysis than using the full 8760-hour annual weather data. It has been suggested that joint-frequency ...
Restoration of Short Periods of Missing Energy Use and Weather Data Using Cubic Spline and Fourier Series Approaches: Qualitative Analysis
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The paper presents seventeen approaches that use
cubic splines and Fourier series for restoring short
term missing data in time series of building energy
use and weather data. The study is based on twenty
samples of hourly ...
Study of the Outside Air Enthalpy Effects in the Screening of Metered Building Energy Data
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
The energy consumption in a building is affected by many parameters including the occupancy, equipment, schedule time, HVAC systems and outside environment conditions. Currently, the outside air dry-bulb temperature (TOA) ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
Continuous Commissioning® of the Dallas/Fort Worth International Airport
(Energy System Laboratory (http://esl.tamu.edu), 2008-10)
The DFW International Airport is one of the largest and busiest airports in the world. Located in North Texas, squarely between the cities of Dallas and Fort Worth, the DFW Airport not only serves a huge population in ...
Use of First Law Energy Balance as a Screening Tool for Building Energy Use Data: Experiences on the Inclusion of Outside Air Enthalpy Variable
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
Quality controlled energy-use data is the foundation of energy performance evaluation for a building. The “Energy Balance Load” (EBL), a parameter derived from the first law of thermodynamics based on a whole-building ...
Development of Data Quality Control Limits for Data Screening through the "Energy Balance" Method
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
Energy management processes such as accounting energy cost, finding overuse in energy, and determining savings from energy conservation programs largely depends on measured energy use data. Identifying and correcting faulty ...
Analysis of Emissions Calculators for the National Center of Excellence on Displaced Emission Reductions (CEDER)- 2008 Annual Report to the United States Environmental Protection Agency
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-02)
In August 2004, the USEPA issued guidance on quantifying the air emission benefits from electric sector
energy efficiency and renewable energy. Because there was no clear best strategy, the EPA’s guidance
provided a ...
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
Analysis of Wind Power Generation of Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-04)