Show simple item record

dc.contributor.otherInternational Pump Users Symposium (31st : 2015)
dc.creatorSilvaggio, Joseph
dc.date.accessioned2017-09-09T21:58:45Z
dc.date.available2017-09-09T21:58:45Z
dc.date.issued2015
dc.identifier.urihttps://hdl.handle.net/1969.1/162189
dc.descriptionCase Studyen
dc.description.abstractDamage to the end head was observed on boiler feed pumps that were running for up to 20 years with reliable service. These boiler feed pumps are high speed, high pressure pumps that supply water to the boilers of power plants of 500 to 800 megawatts. The damage prevented accurate assembly of the seal housing to the end head. The method applied to prevent this damage is the subject of this case study.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratories, Texas A&M Engineering Experiment Station
dc.relation.ispartofProceedings of the 31st International Pump Users Symposiumen
dc.subject.lcshPumping machineryen
dc.titleEliminating Damage By Using Anti-Vortex Vanesen
dc.type.genrePresentationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen
dc.identifier.doihttps://doi.org/10.21423/R1HD02


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record