dc.contributor.other | Turbomachinery Symposium (45th : 2016) | |
dc.creator | Lee, Sangjoo | |
dc.date.accessioned | 2017-03-14T21:29:09Z | |
dc.date.available | 2017-03-14T21:29:09Z | |
dc.date.issued | 2016 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/159781 | |
dc.description | Case Study | en |
dc.description.abstract | The sub-synchronous vibration could be attributed to many causes such as gas-whirl, oil whirl, looseness and so on. To prevent sub-synchronous vibration, manufacturer analyzes stability during design stage. But field condition can be changed because of process issues. Based on actual experience of sub-synchronous vibration in recycle gas compressor of MDU(Middle Distillation Unit) plant, this case study will show how to analyze and reduce vibration without compressor shut down by applying on-stream countermeasure. | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Turbomachinery Laboratories, Texas A&M Engineering Experiment Station | |
dc.relation.ispartof | Proceedings of the 45th Turbomachinery Symposium | en |
dc.subject.lcsh | Turbomachines | en |
dc.title | Analysis and on-stream countermeasures of sub-synchronous vibration of a centrifugal compressor | en |
dc.type.genre | Presentation | en |
dc.type.material | Text | en |
dc.format.digitalOrigin | born digital | en |
dc.identifier.doi | https://doi.org/10.21423/R1MS3X | |