Subsynchronous Vibration In A Large Water Flood Pump
(Texas A&M University. Gas Turbine Laboratories, 1978)
In 1973 Aramco embarked on a large water flood projects for the Ghawar oil reservoir. After approximately 1 year in service three of the 16 X 16 X 20 2-stage DVMF pumps developed a severe shaft vibration of over 20 mils ...