dc.contributor.advisorO'Neal, Dennis L.
dc.creatorDooley, Jeffrey Brandon
dc.date.accessioned2005-02-17T21:03:48Z
dc.date.available2005-02-17T21:03:48Z
dc.date.created2004-12
dc.date.issued2005-02-17
dc.identifier.urihttps://hdl.handle.net/1969.1/1513
dc.description.abstractThree experimental studies were conducted to quantify the effects of system cycling, evaporator airflow, and condenser coil fouling on the performance of residential air conditioners. For all studies, the indoor dry-bulb (db) temperature was 80°F (26.7°C) db. The cycling study consisted of twelve transient tests conducted with an outdoor temperature of 95°F (35°C) db for cycle times of 6, 10, 15, and 24 minutes. Indoor relative humidities of 40%, 50%, and 60% were also considered. The evaporator airflow study consisted of twenty-four steady-state tests conducted with an indoor condition of 67°F (19.4°C) wet-bulb (wb) for evaporator airflows ranging from 50% below to 37.5% above rated airflow. Outdoor temperatures of 85°F (29.4°C) db, 95°F (35°C) db, and 105°F (40.6°C) db were also considered. The coil fouling study used a total of six condensers that were exposed to an outdoor environment for predetermined amounts of time and tested periodically. Three of the condensers were cleaned and retested during the periodic testing cycles. Testing consisted of thirty-three steady-state tests conducted with an indoor condition of 67°F (19.4°C) wb for outdoor exposure times of 0, 2000, 4000, and 8000 hours. Outdoor temperatures of 82°F (27.8°C) db and 95°F (35°C) db were also considered.en
dc.format.extent12844022 bytesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.subjectCyclingen
dc.subjectTransient Dehumidificationen
dc.subjectInstantaneous Capacityen
dc.subjectCyclic Capacityen
dc.subjectMoisture Removal Rateen
dc.subjectEvaporator Airflowen
dc.subjectCondenser Coil Foulingen
dc.titleEffects of System Cycling, Evaporator Airflow, and Condenser Coil Fouling on the Performance of Residential Split-System Air Conditionersen
dc.typeBooken
dc.typeThesisen
thesis.degree.departmentMechanical Engineeringen
thesis.degree.disciplineMechanical Engineeringen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameMaster of Scienceen
thesis.degree.levelMastersen
dc.contributor.committeeMemberCulp, Charles H.
dc.contributor.committeeMemberBryant, John A.
dc.type.genreElectronic Thesisen
dc.type.materialtexten
dc.format.digitalOriginborn digitalen