Browsing by Subject "DOE-2"
Now showing items 1-10 of 10
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)This manual outlines the procedures to collect data, poll the datalogger, and process the data. The processed data is then used with a calibrated DOE-2 input file using statistical graphing routines for the U.S.D.O.E. ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
-
(2012-02-14)The commercial buildings sector in the United States used 18 percent (17.93 Quads) of the U.S. primary energy in 2006. Office buildings are the largest single energy consumption category in the commercial buildings sector ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)DOE-2 yields hourly data on specific variables provided the user specifies the HOURLY-REPORT instruction. Analyzing the simulation results with hourly data gives a more detailed picture of how well the model is predicting ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)EnergyPlus (EPlus) is becoming widely used for building simulation. Previous studies have compared the performance of EPlus with other simulation programs including DOE-2 for a variety of cases. These studies identified ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This is the final report for the ASHRAE 1093-RP project. This report presents the method used to derive the diversity factors and typical load shapes of lighting and receptacle loads in office buildings. In this report the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 1995-12)The intent of this project was to model each of the large buildings at the Karnes County 2,250 bed and Cuero 1,000 bed prison sites with the DOE-2 building energy simulation program and to deliver a working model to the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)This literature review covers the DOE-2 simulation program, which is one of the legacy programs in the ESL’s Emissions Calculator (eCalc), a web-based emissions reductions calculator. The eCalc program is a tool for those ...
-
(2010-10-12)A procedure has been developed for the preliminary selection of high-performance systems for office buildings in hot and humid climates. High-performance building systems and components were surveyed for buildings in the ...
-
(Texas A&M University, 2005-07-27)This thesis documents the usefulness and accuracy of uncalibrated simulations to determine for what end-uses these simulations should be used. The study was divided into three segments 1)comparison of the accuracy of two ...