Browsing by Subject "Commissioning"
Now showing items 1-12 of 12
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)The extensively refurbished heritage government department office building in Canberra's Parliamentary circle, has managed to achieve its target energy performance levels contrary to expectations following difficult design ...
-
(2009-05-15)This thesis compares the variability of commissioning savings and the persistence of savings from the Normalized Annual Consumption (NAC) and standard International Performance Measurement and Verification Protocol (IPMVP) ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because ...
-
(2009-12)More than $18 billion of energy is wasted annually in the U.S. commercial building sector. Commissioning services have proven successful in reducing building energy consumption, but the optimal energy performance obtained ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)The development of Building Energy Management Systems (BEMS) offers new opportunities to automate some aspects of commissioning. Reduction of process cost and manual effort on site, transformation of a one time application ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)The overall efficiency of the Continuous Commissioning (CC) process relies on the interactions of the commissioning team, the building owner, and the building operators. At times the process may be hindered by the traditional ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)This paper presents the results of initial work in developing an ontology for improving information exchange and automation in building system commissioning practices. In our previous research dealing with the derivation ...
-
(2012-07-16)This study evaluated how well energy savings persisted over time in ten university buildings that had undergone retro-commissioning in 1996. The savings achieved immediately following retro-commissioning and in three ...
-
(2008-06-10)The objective of this study is to investigate the reasons why the performance of mechanical systems degrades over time after commissioning and to recommend intervals at which testing should be performed to maintain the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)There is a large selection of sensors available on the market these days. Choosing the correct sensor type for the application is an integral part of ensuring suitable operation. Additionally, once a suitable sensor is ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
-
(2022-06-23)This research studies the estimation of peak electric demand savings as a result of implementing Continuous Commissioning®¹ (CC®) measures in commercial buildings, by using energy modeling, model calibration, and data ...