    • Case Study on investigation and resolution of Dry Gas Secondary Seal Failure 

      Kamal, Girish; Salehan, Fairul Azam Bin (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Dry Gas (DGS) Secondary Seal installed on one of the Flash gas compressor unit at an onshore gas treatment facility failed resulting in equipment downtime and process gas flaring. During detailed tear down inspection, ...
    • In-service Condition Monitoring of Turbine Oils 

      Kamal, Girish (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
      In-service Turbine Oil analysis is an integral part of any Condition Based Maintenance Program and is a vital step in building an effective lubrication strategy. Used correctly, oil analysis on large machinery and engines ...
    • TANDEM DRY GAS SEALS – Design and Maintenance Considerations for Enhanced Reliability and Performance 

      Kamal, Girish (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Dry Gas Seals have been in existence in the process centrifugal compressor industry for the last three decades and majority of the compressor units in operation today are installed with Dry Gas Seals. DGS sealing and the ...